DBS 360

Propaganda
INPUT CH A
INPUT CH B
OVERLOAD CH A/B
560Rx1/2W
INPUT CH A
INPUT CH B
47Rx1/2W
PL280
330R
2K2
560Rx1/2W
100Kx50V
1N4001
10Rx2W
0.47Rx5W
0.47Rx5W
1N4001
100Rx1W
100Rx1W
39pFx500V
BD140
CLIP A
PL280
680R
100R
47uF
47uF
TIP42B
BD139
47Rx1/2W
100Kx50V
47uFx40V
18V
100K
-B
+
CLIP B
OUT A/B
100Kx50V
10K
OUT A/B
10Rx2W
680R
BC327
+
1N4148
10K
AJUSTE
CORRENTE
BD135
100R
1N4148
+
330R
6V2
+
100uF
-B1
PL279
+
10K
8
4K7
100K
12K
33K
1K5
IC1003
470R
6
47K
100pF
6V2
+
47uF 47uF
220R
100uF
4K7
100K
4.7uF
BC557
5
2
3
7
4
2K2
2K2
+B1
15K
VOL. CH B
50KB
2K2
4K7
1N4148
BD140
1
+
CH B
+
39pFx500V
100R
470K
BC337
22pFx100V
BC547
TIP41B
CH A/B
1K
22K
BD139
10K
12K
4K7
AJUSTE OV
2K2
BC557
10K
4.7uF
+
220R
15K
VOL. CH A
50KB
22K
+
470R
18V
100K
CH A
4K7
BC547
47uFx40V
+B
PL230A
CANAL A / CANAL B
EM REPOUSO POT. MÁXIMA
TENSÃO DO TRAFO
TENSÃO DA FONTE (+B)
TENSÃO DA FONTE (-B)
TENSÃO DA FONTE (+B1)
TENSÃO DA FONTE (-B1)
1Kx1W
+B1
8 x 1N4001
PLA005
110V
250V x 10A
+
2200uF
x35V
+
2200uF
x35V
REDE
1000uF
x35V
+B
TDBS360
1000uF
x35V
22OV
-B
+
VISTA
SUPERIOR
+
+B
-B
FONTE
10Kx630V
TERRA EXTERNO
21,0 Vac
+ 25,2 Vdc
- 25,2 Vdc
+ 6,2 Vdc
- 6,2 Vdc
CORRENTE QUIESCENTE 12,7 mA ( 5,9mV DC)*
AJUSTE DE OV
3 mV DC**
ON
2K7x1W
1,5A
PL229
CH A
23,4 Vac
+ 31,9 Vdc
- 31,9 Vdc
+ 6,2 Vdc
- 6,2 Vdc
CH B
1Kx1W
-B1
IC1003
1
2
3
4
5
6
7
8
VISTA FRONTAL
BC 547
BD 135 BC 557
TIP 41B BD 139 BC 327
TIP 42B BD 140 BC 337
EC B
B CE
CBE
Os canais A e B são idênticos.
Todos resistores são de 1/4 W e todos
capacitores eletrolíticos são de 25V,
exceto aqueles com indicação.
* A corrente quiescente deve ser medida
sobre um dos resistores de 0.47Rx5W,
estando o aparelho com carga e sem
sinal de entrada.
** O ajuste de 0V deverá ser feito nos
jacks de saída, estando o aparelho
sem carga e sem sinal de entrada.
INDÚSTRIA
ELETRÔNICA
L T D A.
DBS 360
CIRCUITO: POWER / FONTE
ARQUIVO:..\DBS360_V1.DSN
DATA: 25/05/2001
FOLHA: 01/01
1 - 33
Download